• Standard Number: 1926.500

September 18, 1984

Brian Mentis, Vice President
Integrated Technical Services, Inc.
Post Office Box 10177
Houston, Texas 77206-0177 USA

Dear Mr. Mentis:

This in response to your letter of August 20, 1984, requesting this office to evaluate the ball-type handrail system for use in this country. This also confirms your telephone conversation with Mr. William Simms of my staff.

It is the policy of OSHA not to approve or endorse products. The variable working conditions at jobsites and possible alteration or misapplication of an otherwise safe product could easily create a hazardous condition beyond the control of the product manufacturer.

29 CFR 1926.500(f)(1)(vi) provides that other types, sizes, and arrangements of railing construction are acceptable, provided they meet the following conditions:

(a) A smooth-surfaced top rail at a height above floor, platform, runway, or ramp level of approximately 42 inches. (40 inches high is acceptable.)

(b) A strength to withstand at least the minimum requirement of 200 pounds top rail pressure with a minimum of deflection. (1-11/32 tubing complying with (b) is acceptable.)

(c) Protection between top rail and floor, platform, runway, ramp, or stair treads, equivalent at least to that afforded by a standard intermediate rail.

(d) Elimination of overhang of rail ends unless such overhang does not constitute a hazard.

Railing construction meeting the above criteria may also be used for the protection of employees engaged in general construction work.

In addition, 29 CFR 1926.500(f)(2) requires a stair railing to be of construction similar to a standard railing, but the vertical height shall be not more than 34 inches nor less than 30 inches from upper surface of top rail to surface of tread in line with face of riser at forward edge of tread.

If we can be of further assistance, please let us know.

Sincerely,



John B. Miles, Jr., Director
Directorate of Field Operations


Standard Interpretations - Table of Contents

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.