• Standard Number: 1910.134(e)


May 14, 1984

MEMORANDUM FOR: BYRON R. CHADWICH
Regional Administrator

THRU: JOHN B. MILES, JR., Director
Directorate of Field Operations

EDWARD J. BAIER, Director
Directorate of Technical Support

FROM: RALPH E. YODAIKEN, M.D., Director
Office of Occupational Medicine

SUBJECT: Medical Interpretation - H2S and Respiratory Protection


In our opinion a perforated eardrum is not an impediment to wearing a SCBA positive pressure unless there is fluid behind the ear or other signs of an infection. This implies a proper medical examination by an experienced physician or an ENT specialist before use of the respirator.

However, working in a toxic environment with a perforated eardrum is contraindicated because of the possibility of direct absorption through the perforated drum so certainly we agree with the University of Texas that persons with perforated drums should not be in IDLH (H2S) situations. In fact it seems possible, although we have no confirmation, that the positive pressure may increase the possibility of increased absorption.



March 22, 1984


MEMORANDUM FOR: EDWARD BAIER, Director
Directorate of Technical Support

THRU: JOHN B. MILES, JR., Director
Directorate of Field Operations

FROM: BYRON R. CHADWICK,
Regional Administrator

SUBJECT: Medical Interpretation - H2S and Respirator Protection


This region recently held two training sessions on H2S requirements in the oil production industry. As part of that training, we used a film produced by the University of Texas on respiratory protection and H2S. The film stated that persons with perforated eardrums should not wear SCBA positive pressure in IDLH situations caused by H2S.

The safety director for Gulf Oil in this area called and asked that we review that statement since Gulf's medical department had stated as company policy that this situation was not a danger to employees.

I am requesting that your medical staff give us an opinion on this subject. If you need any other information on this, please contact Bob Glover of my staff. Your prompt attention would be appreciated.



Standard Interpretations - Table of Contents

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.