January 7, 1982

MEMORANDUM FOR: PATRICK TYSON

FROM: R. HAYS BELL

SUBJECT: Evaluation of Winchester Industries Portable Lights for Use in Ship Repair Work


My staff has reviewed and evaluated the material presented to us and our comments are as follows:
Both Maritime Standards, 29 CFR 1915.12(f) and 29 CFR 1915.24(b)(7), state that the U.S. Bureau of Mines is an authorized agency to approve explosion proof lights.

The U.S. Bureau of Mines approved the lights in question on August 17, 1972 and submitted Report BM-506.


This office would, therefore, consider these particular Winchester Industry Lights as permissible.



Archive Notice - OSHA Archive

NOTICE: This is an OSHA Archive Document, and may no longer represent OSHA Policy. It is presented here as historical content, for research and review purposes only.

Standard Interpretations - (Archived) Table of Contents

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close