• Standard Number: 1910.1018

29 CFR 1910.1018

October 6, 1978

Lawrence D. Kornreich, Ph.D.
Environmental Health Associate
ITT World Headquarters
320 Park Avenue
New York, New York 10022

Dear Dr. Kornreich:

This is in response to your letter concerning the applicability of the standard for occupational exposure to inorganic arsenic to operations involving chromated copper arsenate (CCA) wood preservative. Please accept my apology for the delayed response.

On the basis of your telephone conversation with Mr. Gail Brinkerhoff on approximately September 15, 1978, it is understood that you are referring to the manufacture of CCA wood preservative for internal plant use only. It is also understood on the basis of that telephone conversation that the preservative is prepared in a mixing (or reaction) vessel from base chemicals. The preservative is then pumped to a holding vessel from which it is pumped into the vessel where the treatment of the wood takes place. When the treatment of wood is complete, the preservative remaining in the treatment vessel is then recycled back to the holding vessel.

The Environmental Protection Agency's regulations do not apply at any stage in a process where wood preservatives are manufactured for internal plant use only and are not sold as a commercial product. Occupational Safety and Health Administration standard 29 CFR 1910.1018, published in the Federal Register on May 5, 1978, applies up to the point where the CCA wood preservative enters the pipeline running from the holding vessel to the treatment vessel.

The answers to your specific questions assuming manufacture of CCA wood preservative for internal plant use only are as follows:

1. An employee mixing CCA and applying it to the wood is covered by 29 CFR 1910.1018 until he/she moves beyond the preservative holding vessel. Neither EPA or OSHA regulations apply beyond the holding vessel.

2. An employee mixing CCA is covered by 29 CFR 1910.1018 during all stages of the operation.

Thank you for your interest in occupational health.

Sincerely,



Bruce Hillenbrand
Acting Director,
Federal Compliance
and State Programs


Standard Interpretations - Table of Contents

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.