• Standard Number: 1926.28; 1926.105; 1926.750
• Status: Archived

Archive Notice - OSHA Archive

NOTICE: This is an OSHA Archive Document, and may no longer represent OSHA Policy. It is presented here as historical content, for research and review purposes only.

October 5, 1978

Mr. Russell E. Jones
P.O. Box 2268
Tucson, Arizona 85702

Dear Mr. Jones:

This is in response to your letters of August 10, and September 7, 1978. In your letter you posed the question: "Is an iron worker connector required to tie off when performing work as a connector and when going to and from such work?"

An iron worker may be exposed to many unique hazards among which is the severe hazard of falling. Due to the nature of the work, a fall often results in serious physical harm and/or death. The problems associated with safety protection for iron workers, within a constantly changing environment, are complex. To specifically direct any one form of protection is not OSHA's intent nor do the regulations so require. The employer is required, however, under the law, to provide safeguards for his employees. Tie offs may, under some circumstances, offer hazard to iron workers operating as connectors. Safeguards such as safety nets may be rigged beneath the workers in lieu of tie offs. In either events, the iron worker's safety must be provided for.

Regarding the access and egress of the iron worker while proceeding to and from work locations upon the structure being erected, the iron worker shall be protected from injurious falls by some safety precautionary measures determined appropriate and implemented by the employer.

Coordination with the Lubbock Area Office revealed that the citation issued under 29 CFR 1926.28(a) also referenced 29 CFR 1926.105(a), and various alternates providing worker protection from injurious falls. The files indicate no protection of any sort had been afforded by the employer.

In conclusion, a requirement for the tie off or iron workers while performing connector operations is not always required and indeed such procedure may be more hazardous. However, an alternative form of protection must be provided by the employer. Protection from falls must also be provided during access and egress. Reference 29 CFR 1926.750(b)(1)(ii); 29 CFR 1926.28(a) and (b); and 29 CFR 1926.105.

If I may be of further assistance, please do not hesitate to contact me.

Sincerely,



John K. Barto, Chief
Division of Occupational
Safety Programming


Archive Notice - OSHA Archive

NOTICE: This is an OSHA Archive Document, and may no longer represent OSHA Policy. It is presented here as historical content, for research and review purposes only.

Standard Interpretations - (Archived) Table of Contents

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close