Standard Cited: 5A0001 OSH Act General Duty Paragraph

Violation Items

Nr: 309525202 Citation: 01001 Issuance: 05/09/2006 ReportingID: 0215000

Viol Type:Serious NrInstances:1 Contest Date:
Abatement Date:06/11/2006 X Nr Exposed:6 Final Order:
Initial Penalty: $7,000.00 REC:A Emphasis:
Current Penalty: $4,620.00 Gravity:10 Haz Category:CRUSHING

Penalty and Failure to Abate Event History
Type Event Date Penalty Abatement Type FTA Insp
Penalty Z: Issued 05/09/2006 $7,000.00 06/11/2006 Serious  
Penalty I: Informal Settlement 06/05/2006 $4,620.00 06/11/2006 Serious  

Text For Citation: 01 Item/Group: 001 Hazard: CRUSHING

Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that the employees were exposed to falling, and crushing hazards. a)Elevator shaft doors/gate on the 1st floor, 4th floor, and 7th floor. On or about 12/16/05 The elevator shaft doors/gate did not self close.. b)Elevator shaft doors/gate throughout the building. The elevator car doors/gate were not electronically interlocked to prevent movement of the elevator when the hoist doors/gate were open. c)Elevator car. The elevator car had no walls or roof. d)Elevator on site. The elevator was not equipped with a car safety devices. e)Elevator on site. The capacity of the elevator was not posted. ONE FEASIBLE AND ACCEPTABLE ABATEMENT METHOD, AMONG OTHERS, TO CORRECT THIS HAZARD IS: to follow ASME A 17.3-1993 Safety Code for Existing Elevators. -Section 2.6.2 "Closing of Hoistway Doors" which states that hoistway doors shall self close. -Section 2.7.1 "Hoistway Door or Gate Locking Devices" which states that these gates require electro-mechanical interlocks to keep them closed when the elevator is moving, and Section 2.7.4 "Restricted Opening of Hoistway Doors" which states that the hoistway door shall prevent the opening of the door when the elevator is not in the landing zone. -Section 3.4.1 "Car Enclosures" Which states that cars shall be fully enclosed on all non- entrance sides and on top. -Section 3.5.1 "Car Safeties" which states that safeties shall pe provided to stop the car with its full rated load from the governor tripping speed. -Section 3.7.4 "Capacity Plates" Which states that every elevator shall have a capacity plate. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION AND DOCUMENTATION FOR THIS ITEM IN ACCORDANCE WITH 29 CFR 1903.19NCE

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close