Case Status: CLOSED
Inspection: 997570.015 - H.M. Richards, Inc.

Inspection Information - Office: Jackson

Nr: 997570.015Report ID: 0419400Open Date: 10/02/2014

H.M. Richards, Inc.
145 Towery Road
Guntown, MS 38849
Union Status: NonUnion
SIC:
NAICS: 337121/Upholstered Household Furniture Manufacturing
Mailing: P. O. Box 373, Baldwyn, MS 38824

Inspection Type:Fat/Cat
Scope:Complete Advanced Notice:Y
Ownership:Private
Safety/Health:Safety Close Conference:12/09/2014
Emphasis: L:Forklift, N:Dustexpl, N:AmputateClose Case:05/19/2015

Related Activity:TypeIDSafetyHealth
 Accident911828    
Case Status: CLOSED

Violation Summary
Serious Willful Repeat Other Unclass Total
Initial Violations 7 1 1 9
Current Violations 7 2 9
Initial Penalty $38,600 $0 $16,500 $0 $0 $55,100
Current Penalty $32,100 $0 $0 $1,000 $0 $33,100
FTA Amount $0 $0 $0 $0 $0 $0

Violation Items
# ID Type Standard Issuance Abate Curr$ Init$ Fta$ Contest LastEvent
  1. 01001 Serious 19100212 A03 II 02/27/2015 $4,000 $5,500 $0 I - Informal Settlement
  2. 01002 Other 19100215 B09 02/27/2015 03/23/2015 $1,000 $3,300 $0 I - Informal Settlement
  3. 01003 Serious 19100303 G02 I 02/27/2015 $4,200 $7,000 $0 I - Informal Settlement
  4. 01004 Serious 19100304 A01 02/27/2015 $2,450 $4,400 $0 I - Informal Settlement
  5. 01005 Serious 19100304 G05 02/27/2015 $2,450 $4,400 $0 I - Informal Settlement
  6. 01006A Serious 19100332 B01 02/27/2015 03/23/2015 $6,000 $7,000 $0 I - Informal Settlement
  7. 01006B Serious 19100334 C01 02/27/2015 03/23/2015 $0 $0 $0 I - Informal Settlement
  8. 01007 Serious 19100333 B02 02/27/2015 $6,000 $7,000 $0 I - Informal Settlement
  9. 02001 Serious 19100303 F02 02/27/2015 $7,000 $16,500 $0 I - Informal Settlement
  10. 03001 Other 19100305 G02 III 02/27/2015 $0 $0 $0 I - Informal Settlement

Accident Investigation Summary
Summary Nr: 68294.015Event: 10/01/2014Employee Is Electrocuted While Disconnecting A Gang Saw
At 11:15 a.m. on October 1, 2014, an employee was disconnecting a gang saw from the electric power to relocate it to another facility. The employee contacted an energized wire and was electrocuted. The current entered the employee through his hands. The saw was powered by a 480 volt 3 phase connection. However, only one phase was energized leaving a voltage of 281 volts to ground and a 110 amp fuse.
Keywords: saw, electrocuted, electrical
Inspection Degree Nature Occupation
1 997570.015 Fatality Electric Shock Machinery maintenance occupations

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.