Powered by GoogleTranslate

Occupational Safety and Health Administration OSHA

Inspection Detail

Inspection: 672618.015 - Mid-Atlantic Realty Co., Inc.

Inspection Information - Office: Wilmington

Nr: 672618.015Report ID: 0317300Open Date: 10/08/2012

Mid-Atlantic Realty Co., Inc.
248 Presidential Drivenull
Greenville, DE 19807
Union Status: NonUnion
SIC:
NAICS: 531311/Residential Property Managers
Mailing: 248 Presidential Drivenull, Greenville, DE 19807

Inspection Type:Fat/Cat
Scope:Complete Advanced Notice:N
Ownership:Private
Safety/Health:Safety Close Conference:04/02/2013
Emphasis: L:FallClose Case:11/06/2013

Related Activity:TypeIDSafetyHealth
 Accident602490 Yes  

Violation Summary
Serious Willful Repeat Other Unclass Total
Initial Violations 5 1 6
Current Violations 3 3 6
Initial Penalty $29,390 $0 $0 $0 $0 $29,390
Current Penalty $16,646 $0 $0 $6,354 $0 $23,000
FTA Amount $0 $0 $0 $0 $0 $0

Violation Items
# ID Type Standard Issuance Abate Curr$ Init$ Fta$ Contest LastEvent
  1. 01001 Serious 5A0001 04/05/2013 $6,532 $7,000 $0 I - Informal Settlement
  2. 01002A Serious 19100067 C02 XI 04/05/2013 $6,532 $7,000 $0 I - Informal Settlement
  3. 01002B Serious 19100067 C02 II 04/05/2013 $0 $4,050 $0 I - Informal Settlement
  4. 01003 Serious 19100067 B02 04/05/2013 $3,582 $4,050 $0 I - Informal Settlement
  5. 01005 Other 19100067 C02 IX 04/05/2013 $3,582 $4,050 $0 I - Informal Settlement
  6. 01006A Other 19101200 E01 04/05/2013 06/17/2013 $2,772 $3,240 $0 I - Informal Settlement
  7. 01006B Other 19101200 H03 III 04/05/2013 06/17/2013 $0 $0 $0 I - Informal Settlement
  8. 02001 Other 19100157 G02 04/05/2013 05/17/2013 $0 $0 $0 I - Informal Settlement

Accident Investigation Summary
Summary Nr: 41243.015Event: 10/08/2012Employee Operating Aerial Device Contacts Power Line Is Elec
At approximately 4:15 p.m. on October 8, 2012, Employee #1 was inside a fibergla ss bucket of a truck mounted aerial device, Holan 819 Aerial device. The aerial device had multiple modifications that were not approved by the manufacturer whi ch reduced the inherent electrical insulation value engineered into the device. The devices hydraulic systems bursting safety factor were weakened. While standi ng in the bucket the upper boom contacted an overhead energized, 750 volt, bare power line. An inferno ensued as the electrical current ignited hydraulic fluid released under pressure. Employee #1 was electrocuted.
Keywords: aerial lift, combustible liquid, construction vehicle, electrical, elevated work platform, explosion, hydraulic lift, power lines
Inspection Degree Nature Occupation
1 672618.015 Fatality Carpenter

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.