Powered by GoogleTranslate

Occupational Safety and Health Administration OSHA

Inspection Detail

Inspection: 444073.015 - Arens Controls Company, Llc

Inspection Information - Office: Chicago North

Nr: 444073.015Report ID: 0524200Open Date: 05/22/2012

Arens Controls Company, Llc
3602 N. Kennicott Avenuenull
Arlington Heights, IL 60004
Union Status: NonUnion
SIC:
NAICS: 336399/All Other Motor Vehicle Parts Manufacturing
Mailing: 3602 N. Kennicott Avenuenull, Arlington Heights, IL 60004

Inspection Type:Fat/Cat
Scope:Partial Advanced Notice:N
Ownership:Private
Safety/Health:Health Close Conference:11/14/2012
Close Case:03/11/2013

Related Activity:TypeIDSafetyHealth
 Accident362787    

Violation Summary
Serious Willful Repeat Other Unclass Total
Initial Violations 5 5
Current Violations 5 5
Initial Penalty $26,100 $0 $0 $0 $0 $26,100
Current Penalty $26,100 $0 $0 $0 $0 $26,100
FTA Amount $0 $0 $0 $0 $0 $0

Violation Items
# ID Type Standard Issuance Abate Curr$ Init$ Fta$ Contest LastEvent
  1. 01001 Serious 5A0001 11/20/2012 01/09/2013 $6,300 $6,300 $0 Z - Issued
  2. 01002 Serious 19100147 C04 I 11/20/2012 01/09/2013 $6,300 $6,300 $0 Z - Issued
  3. 01003 Serious 19100307 B 11/20/2012 01/09/2013 $4,500 $4,500 $0 Z - Issued
  4. 01004 Serious 19100307 C03 11/20/2012 01/09/2013 $6,300 $6,300 $0 Z - Issued
  5. 01005 Serious 19101200 G01 11/20/2012 01/09/2013 $2,700 $2,700 $0 Z - Issued

Accident Investigation Summary
Summary Nr: 17715.015Event: 05/22/2012Employee Is Killed By Explosion Of Hod Chamber
At approximately 8:45 a.m. on May 22, 2012, Employee #1 was troubleshooting a th ermal chamber, evaluating a Hydrogen on Demand (HOD) unit. The chamber was repo rted inoperative that morning. Two units were being tested on a work bench and they were connected by an exhaust hose to an HOD inside the test chamber. The g as was not properly exhausted and began to back up into the hose that was attach ed to the HOD. Employee #1 removed the side panel on the chamber and it explode d while he were standing in front of it. The local fire department responded an d pulled Employee #1 from the building. Employee #1 was killed as a result of b lunt force trauma to his head and body caused by the explosion.
Keywords: exhaust fumes, explosion, head
Inspection Degree Nature Occupation
1 444073.015 Fatality

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close