Powered by GoogleTranslate

Occupational Safety and Health Administration OSHA

Inspection Detail

Inspection: 316512839 - Harbor Marine, Inc.

Inspection Information - Office: Maryland Region 1

Nr: 316512839Report ID: 0352410Open Date: 08/08/2012

Harbor Marine, Inc.
12731 Sunset Avenue
Ocean City, MD 21842
Union Status: NonUnion
SIC: 5551/Boat Dealers
NAICS: 441222/Boat Dealers

Inspection Type:Accident
Scope:Partial Advanced Notice:N
Ownership:Private
Safety/Health:Safety Close Conference:08/17/2012
Emphasis: L:Accident, S:Ttu 220000&420000-490000Close Case:10/16/2012

Related Activity:TypeIDSafetyHealth
 Accident102596574    

Violation Summary
Serious Willful Repeat Other Unclass Total
Initial Violations 4 3 7
Current Violations 4 3 7
Initial Penalty $7,425 $0 $0 $0 $0 $7,425
Current Penalty $4,678 $0 $0 $0 $0 $4,678
FTA Amount $0 $0 $0 $0 $0 $0

Violation Items
# ID Type Standard Issuance Abate Curr$ Init$ Fta$ Contest LastEvent
  1. 01001 Serious 19100132 F01 09/26/2012 11/13/2012 $772 $1,225 $0 I - Informal Settlement
  2. 01002 Serious 19101200 E01 09/26/2012 11/13/2012 $882 $1,400 $0 I - Informal Settlement
  3. 01003 Serious 19101200 G01 09/25/2012 10/03/2012 $1,512 $2,400 $0 I - Informal Settlement
  4. 01004 Serious 19101200 H01 09/26/2012 11/13/2012 $1,512 $2,400 $0 I - Informal Settlement
  5. 02001 Other 19100132 D02 09/26/2012 10/04/2012 $0 $0 $0 I - Informal Settlement
  6. 02002 Other 50405 B01 09/26/2012 10/04/2012 $0 $0 $0 I - Informal Settlement
  7. 02003 Other 50406 A01 09/26/2012 10/22/2012 $0 $0 $0 I - Informal Settlement

Accident Investigation Summary
Summary Nr: 202635660Event: 08/08/2012Burns From Flash Fire
Employee #1 was finishing the installation of a bilge pump. Employee #1 had installed the bilge pump to the bottom of the boat hull in the bilge area and was attempting to melt two pieces of shrink tubing around the electric wires that ran from the battery to the pump. There was gasoline located in the bilge because the gasoline was never cleaned up, or flushed from the boats bilge. When Employee #1 was melting the shrink tubing he ignited the gasoline vapors creating a flash fire. Employee #1 received third degree burns to his hands, arms, and face.
Keywords: battery, burn, fire, gas, arm, face, pump, hand, boat
Inspection Degree Nature Occupation
1 316512839 Hospitalized injury Other Not specified mechanics and repairers

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close