Inspection Detail
Inspection Information - Office: Nc Raleigh | ||||
---|---|---|---|---|
Nr: 314372921 | Report ID: 0453710 | Open Date: 04/20/2010 | ||
Pike Electric, Inc. | ||||
Fenner Road/Greyson Road (Corner) Rocky Mount, NC 27803 | Union Status: NonUnion | |||
SIC: 1731/Electrical Work | ||||
NAICS: 238210/Electrical Contractors | ||||
Mailing: P.O. Box 868, Mount Airy, NC 27030 | ||||
Inspection Type: | Accident | |||
Scope: | Partial | Advanced Notice: | N | |
Ownership: | Private | |||
Safety/Health: | Safety | Close Conference: | 10/11/2010 | |
Planning Guide: | Safety-Construction | Close Case: | 01/10/2011 | |
Emphasis: | L:Commcon | |||
Related Activity: | Type | ID | Safety | Health |
Accident | 100361161 |
Violation Summary | ||||||
---|---|---|---|---|---|---|
Serious | Willful | Repeat | Other | Unclass | Total | |
Initial Violations | 1 | 1 | ||||
Current Violations | 1 | 1 | ||||
Initial Penalty | $6,300 | $0 | $0 | $0 | $0 | $6,300 |
Current Penalty | $6,300 | $0 | $0 | $0 | $0 | $6,300 |
FTA Amount | $0 | $0 | $0 | $0 | $0 | $0 |
Violation Items | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
# | ID | Type | Standard | Issuance | Abate | Curr$ | Init$ | Fta$ | Contest | LastEvent | |
1. | 01001 | Serious | 19260550 A01 | 10/13/2010 | 10/18/2010 | $6,300 | $6,300 | $0 | I - Informal Settlement |
Accident Investigation Summary | ||||||
Summary Nr: 200358430 | Event: 04/20/2010 | Employee Is Killed When Thrown From Truck | ||||
At or around 9:30 a.m. on April 20, 2010, Employee #1 was thrown from the operator's seat of a "Digger Derrick" truck while attempting to lift an engineered steel pole with the crane located at the rear of the truck. Employee #1 was killed in the incident. | ||||||
Keywords: ejected, vehicle, equipment operator, metal pole, aerial lift, crane | ||||||
Inspection | Degree | Nature | Occupation | |||
---|---|---|---|---|---|---|
1 | 314372921 | Fatality | Other | Electrical power installers and repairers |