Inspection Detail
Inspection: 309702553 - 52mco Refrigeration, Inc.
|
Inspection Information - Office: Cincinnati | ||||
Nr: 309702553 | Report ID: 0522000 | Open Date: 02/17/2006 | ||
52mco Refrigeration, Inc. | ||||
2450 Dayton Xenia Rd. Beaver Creek, OH 45430 | Union Status: NonUnion | |||
SIC: 7699/Repair Shops and Related Services, Not Elsewhere Classified | ||||
NAICS: 238220/ Plumbing, Heating, and Air-Conditioning Contractors | ||||
Mailing: 4230 Leston Ave, Dayton, OH 45424 | ||||
Inspection Type: | Referral | |||
Scope: | Partial | Advanced Notice: | N | |
Ownership: | Private | |||
Safety/Health: | Safety | Close Conference: | 02/22/2006 | |
Close Case: | 09/07/2006 | |||
Related Activity: | Type | ID | Safety | Health |
Referral | 201954179 | Yes |
Serious | Willful | Repeat | Other | Unclass | Total | |
---|---|---|---|---|---|---|
Initial Violations | 3 | 3 | ||||
Current Violations | 2 | 2 | ||||
Initial Penalty | $2,400 | $0 | $0 | $0 | $0 | $2,400 |
Current Penalty | $850 | $0 | $0 | $0 | $0 | $850 |
FTA Amount | $0 | $0 | $0 | $0 | $0 | $0 |
# | ID | Type | Standard | Issuance | Abate | Curr$ | Init$ | Fta$ | Contest | LastEvent | |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Serious | 19101200 H01 | 03/08/2006 | 04/24/2006 | $650 | $1,500 | $0 | I - Informal Settlement | ||
Deleted | 2. | 01002 | Serious | 19101200 G08 | 03/08/2006 | 04/03/2006 | $0 | $450 | $0 | I - Informal Settlement | |
3. | 01003 | Serious | 19101200 E01 | 03/08/2006 | 04/24/2006 | $200 | $450 | $0 | I - Informal Settlement |
Accident Investigation Summary | ||||||
---|---|---|---|---|---|---|
Summary Nr: 201954518 | Event: 02/14/2006 | Employee Is Injured In Explosion | ||||
On February 14, 2006, Employee #1 was repairing a refrigeration line. As Employee #1 pumped oxygen into the refrigeration line, instead of nitrogen, an explosion occurred. Employee #1 was hospitalized and treated for his injuries, which included hearing loss. | ||||||
Keywords: ear, gas, refrigerant, explosion, hearing loss, chemical reaction | ||||||
Inspection | Degree | Nature | Occupation | |||
1 | 309702553 | Hospitalized injury | Hearing Loss | Occupation not reported |