Inspection Detail
Inspection: 303576284 - Metal Spray North America
|
Inspection Information - Office: South Carolina Priv | ||||
Nr: 303576284 | Report ID: 0454510 | Open Date: 10/30/2000 | ||
Metal Spray North America | ||||
4001 Mccords Ferry Rd. Eastover, SC 29044 | Union Status: NonUnion | |||
SIC: 1711/Plumbing, Heating and Air-Conditioning | ||||
Mailing: 11600 Busy St., Suite 202, Richmond, VA 23236 | ||||
Inspection Type: | Accident | |||
Scope: | Partial | Advanced Notice: | N | |
Ownership: | Private | |||
Safety/Health: | Health | Close Conference: | 01/16/2001 | |
Planning Guide: | Health-Construction | Close Case: | 07/26/2001 | |
Related Activity: | Type | ID | Safety | Health |
Accident | 100371699 |
Serious | Willful | Repeat | Other | Unclass | Total | |
---|---|---|---|---|---|---|
Initial Violations | 6 | 6 | ||||
Current Violations | 6 | 6 | ||||
Initial Penalty | $5,875 | $0 | $0 | $0 | $0 | $5,875 |
Current Penalty | $2,350 | $0 | $0 | $0 | $0 | $2,350 |
FTA Amount | $0 | $0 | $0 | $0 | $0 | $0 |
# | ID | Type | Standard | Issuance | Abate | Curr$ | Init$ | Fta$ | Contest | LastEvent | |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Serious | 19100146 D04 | 01/31/2001 | 02/06/2001 | $350 | $875 | $0 | 02/23/2001 | F - Formal Settlement | |
2. | 01002 | Serious | 19100146 D05 | 01/31/2001 | 02/06/2001 | $600 | $1,500 | $0 | 02/23/2001 | F - Formal Settlement | |
3. | 01003 | Serious | 19100146 E05 | 01/31/2001 | 02/06/2001 | $350 | $875 | $0 | 02/23/2001 | F - Formal Settlement | |
4. | 01004 | Serious | 19100146 F | 01/31/2001 | 02/06/2001 | $350 | $875 | $0 | 02/23/2001 | F - Formal Settlement | |
5. | 01005 | Serious | 19100146 G04 | 01/31/2001 | 02/06/2001 | $350 | $875 | $0 | 02/23/2001 | F - Formal Settlement | |
6. | 01006 | Serious | 19100146 J01 | 01/31/2001 | 02/06/2001 | $350 | $875 | $0 | 02/23/2001 | F - Formal Settlement |
Accident Investigation Summary | ||||||
---|---|---|---|---|---|---|
Summary Nr: 200371292 | Event: 10/14/2000 | Employee Dies From Metal Fume Fever | ||||
An employee was performing maintenance on a paper mill recovery boiler. He was working in close proximity to a metallizing operation where a chrome/nickel protective coating was being applied (sprayed) to the interior of the boiler. The employee became ill after an unknown period of time and was hospitalized. He was diagnosed with metal fume fever due to exposure to chromium and nickel fumes, and later died from his illness. | ||||||
Keywords: maintenance, boiler, air contamination, toxic fumes, overexposure, chemical | ||||||
Inspection | Degree | Nature | Occupation | |||
1 | 303576284 | Fatality | Poisoning(Systemic) | Miscellaneous precision metal workers |