Inspection Detail
Inspection Information - Office: Nc Raleigh | ||||
---|---|---|---|---|
Nr: 302125695 | Report ID: 0453710 | Open Date: 07/30/1998 | ||
Georgia Electric Company | ||||
Club & Glendale Ave Durham, NC 27701 | Union Status: NonUnion | |||
SIC: 1731/Electrical Work | ||||
Mailing: P.O. Box 3108, Albany, GA 31706 | ||||
Inspection Type: | Accident | |||
Scope: | Partial | Advanced Notice: | N | |
Ownership: | Private | |||
Safety/Health: | Safety | Close Conference: | 07/30/1998 | |
Planning Guide: | Safety-Construction | Close Case: | 01/05/2011 | |
Related Activity: | Type | ID | Safety | Health |
Accident | 100351394 |
Violation Summary | ||||||
---|---|---|---|---|---|---|
Serious | Willful | Repeat | Other | Unclass | Total | |
Initial Violations | 2 | 2 | ||||
Current Violations | 2 | 2 | ||||
Initial Penalty | $8,750 | $0 | $0 | $0 | $0 | $8,750 |
Current Penalty | $6,563 | $0 | $0 | $0 | $0 | $6,563 |
FTA Amount | $0 | $0 | $0 | $0 | $0 | $0 |
Violation Items | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
# | ID | Type | Standard | Issuance | Abate | Curr$ | Init$ | Fta$ | Contest | LastEvent | |
1. | 01001A | Serious | 19100268 B07 | 09/17/1998 | 10/05/1998 | $4,725 | $6,300 | $0 | I - Informal Settlement | ||
2. | 01001B | Serious | 19100268 E | 09/17/1998 | 10/05/1998 | $0 | $0 | $0 | I - Informal Settlement | ||
3. | 01002 | Serious | 19260453 B02 V | 09/17/1998 | 10/05/1998 | $1,838 | $2,450 | $0 | I - Informal Settlement |
Accident Investigation Summary | ||||||
Summary Nr: 200350742 | Event: 07/29/1998 | Electric Shock - Contact With Overhead Line Thru Guy | ||||
An electrical contractor was upgrading a city's traffic control system. An employee working on this job was in an aerial lift, attaching an aerial guy to pole-mounted hardware. He was about 7.6 meters above the ground. As he was pulling the guy up, it contacted a 7200-volt overhead power line. The employee received an electric shock and sustained burns on his right hand. He was hospitalized for his injuries. | ||||||
Keywords: burn, overhead power line, electrical, electrical work, e c, guy, electric shock, aerial lift | ||||||
Inspection | Degree | Nature | Occupation | |||
---|---|---|---|---|---|---|
1 | 302125695 | Hospitalized injury | Electric Shock | Urban planners |