Inspection: 15302698 - Miller Technical Service

Inspection Information - Office: Nc Raleigh

Nr: 15302698Report ID: 0453710Open Date: 10/30/1986

Miller Technical Service
3311 Griffith St
Charlotte, NC 28203
Union Status: NonUnion
SIC: 7629/Electrical and Electronic Repair Shops, Not Elsewhere Classified
Mailing: Rt 1 Box 136-T, New London, NC 28127

Inspection Type:Accident
Scope:Partial Advanced Notice:N
Ownership:Private
Safety/Health:Safety Close Conference:10/30/1986
Close Case:10/30/1986

Related Activity:TypeIDSafetyHealth
 Accident360767800    

Accident Investigation Summary
Summary Nr: 14254387Event: 10/29/1986Electric Shock - Direct Contact With Energized Parts
AN ELECTRIC EQUIPMENT REPAIRER WAS USING A HAND-HELD MULTIMETER TO TEST THE ELECTRICAL CIRCUITRY OF A GENERAL ELECTRIC 50-KILOWATT INDUCTION HEAT TREATING MACHINE. THE MACHINE WAS STILL ENERGIZED, AND THE EMPLOYEE WAS ELECTROCUTED WHEN HE CONTACTED A LIVE PART WITH HIS LEFT HAND.
Keywords: e gi ii, elec protect equip, electrical, electrician, electrocuted, electrical work, test equipment, elec equipment--misc
Inspection Degree Nature Occupation
1 15302698 Fatality Electric Shock Misc. electrical & electronic equipment repairers

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.