Inspection Detail
Case Status: CLOSED |
Inspection: 1508175.015 - Stinky Pinky Inc
|
Inspection Information - Office: Tenn Cmpl Sfty 2 | ||||
Nr: 1508175.015 | Report ID: 0454712 | Open Date: 12/29/2020 | ||
Stinky Pinky Inc | ||||
5931 Hwy 41a Joelton, TN 37080 | Union Status: NonUnion | |||
SIC: | ||||
NAICS: 562991/Septic Tank and Related Services | ||||
Mailing: P.O. Box 3717, Clarksville, TN 37043 | ||||
Inspection Type: | Fat/Cat | |||
Scope: | Partial | Advanced Notice: | N | |
Ownership: | Private | |||
Safety/Health: | Safety | Close Conference: | 01/21/2021 | |
Close Case: | 06/03/2022 | |||
Related Activity: | Type | ID | Safety | Health |
Accident | 1713092 |
Case Status: CLOSED |
Serious | Willful | Repeat | Other | Unclass | Total | |
---|---|---|---|---|---|---|
Initial Violations | 2 | 2 | ||||
Current Violations | 2 | 2 | ||||
Initial Penalty | $0 | $0 | $0 | $200 | $0 | $200 |
Current Penalty | $0 | $0 | $0 | $200 | $0 | $200 |
FTA Amount | $0 | $0 | $0 | $0 | $0 | $0 |
# | ID | Type | Standard | Issuance | Abate | Curr$ | Init$ | Fta$ | Contest | LastEvent | |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Other | TDLWD RULE 800-01-03-.03(27)(A) | 02/01/2021 | 02/16/2021 | $100 | $100 | $0 | Z - Issued | ||
2. | 01002 | Other | TDLWD RULE 800-01-03-.05(1)(A)2 | 02/01/2021 | 02/16/2021 | $100 | $100 | $0 | Z - Issued |
Accident Investigation Summary | ||||||
---|---|---|---|---|---|---|
Summary Nr: 132032.015 | Event: 12/02/2020 | Employee Is Killed After Being Struck By Vehicle | ||||
At approximately 7:30 a.m. on December 2, 2020, an employee was loading trash bi ns. The employee was struck by a motor vehicle. The employee was killed after in juries to the leg, pelvis as well as other unspecified injuries. | ||||||
Keywords: leg, motor vehicle, pelvis, struck by, trash bin, vehicle | ||||||
Inspection | Degree | Nature | Occupation | |||
1 | 1508175.015 | Fatality |