Inspection: 1501077.015 - Mmr Constructors Inc.

Inspection Information - Office: Atlanta East

Nr: 1501077.015Report ID: 0418100Open Date: 11/05/2020

Mmr Constructors Inc.
1760 Steve Reynolds Pkwynull
Commerce, GA 30529
Union Status: NonUnion
SIC:
NAICS: 238210/Electrical Contractors
Mailing: 15961 Airline Hwy.Null, Baton Rouge, LA 70817

Inspection Type:Fat/Cat
Scope:Complete Advanced Notice:N
Ownership:Private
Safety/Health:Safety Close Conference:11/05/2020
Emphasis: L:FallClose Case:09/30/2021

Related Activity:TypeIDSafetyHealth
 Referral1682875 Yes  
 Accident1687895    
 Inspection1502789 Yes  

Violation Summary
Serious Willful Repeat Other Unclass Total
Initial Violations 2 2
Current Violations 1 1
Initial Penalty $27,306 $0 $0 $0 $0 $27,306
Current Penalty $0 $0 $0 $13,653 $0 $13,653
FTA Amount $0 $0 $0 $0 $0 $0

Violation Items
# ID Type Standard Issuance Abate Curr$ Init$ Fta$ Contest LastEvent
Deleted 1. 01001 Serious 19260501 B04 II 04/30/2021 05/19/2021 $13,653 $13,653 $0 I - Informal Settlement
  2. 01002 Other 19260502 D08 04/30/2021 05/19/2021 $13,653 $13,653 $0 I - Informal Settlement

Accident Investigation Summary
Summary Nr: 130910.015Event: 11/04/2020Foreman Is Killed In Fall And Coworker Is Struck And Injured
At 10:45 a.m. on November 4, 2020, Employee #1, Coworker #1, and other coworkers , employed by an electrical contractor, were engaged in electrical wiring instal lation work at a multi-employer construction project, a new commercial building. Employee #1, the crew foreman, was directing an installation crew in bay five while Coworker #1 was doing clean-up work on a lower level. Employee #1, wearin g a full body harness but not tied to a self-retracting lanyard or a lifeline, s tepped on an uncovered draft vent opening in the walking surface. He fell throu gh the opening, a fall height of 52 feet, and struck Coworker #1 and the concret e floor on the lower level. Employee #1 and Coworker #1 were transported to the hospital. Employee #1 died at the hospital on November 16, 2020. Coworker #1 was hospitalized for treatment of injuries.
Keywords: blunt force trauma, ceiling, concrete, construction, electrical work, electrician, fall, fall protection, floor hole, floor opening, fracture, installing, multi-employer worksite, ppe, struck against, unguarded fl o
Inspection Degree Nature Occupation
1 1501077.015 Hospitalized injury Electricians' apprentices
2 1501077.015 Fatality Electrical power installers and repairers

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.