Inspection: 1478050.015 - Meridian Precision, Inc.

Inspection Information - Office: Wilkes-Barre

Nr: 1478050.015Report ID: 0317700Open Date: 06/08/2020

Meridian Precision, Inc.
80 Roberts Roadnull
Pine Grove, PA 17963
Union Status: NonUnion
SIC:
NAICS: 326199/All Other Plastics Product Manufacturing
Mailing: Po Box 206null, Pine Grove, PA 17963

Inspection Type:Fat/Cat
Scope:Partial Advanced Notice:N
Ownership:Private
Safety/Health:Safety Close Conference:06/08/2020
Close Case:11/03/2020

Related Activity:TypeIDSafetyHealth
 Accident1601926    

Accident Investigation Summary
Summary Nr: 126809.015Event: 06/06/2020Employee Is Electrocuted While Doing Maintenance On Shredder
At 2:00 p.m. on June 6, 2020, Employee # 1, the owner, was performing maintenanc e on the shredder conveyor system. The electrical cord to the conveyor was still plugged in and energized (480 volt). Employee # 1 cut a wire in the cord plug u sing a pair of wire strippers. He was electrocuted and was killed.
Keywords: conveyor, cut, electrocuted, maintenance
Inspection Degree Nature Occupation
1 1478050.015 Fatality Chief exec's & gen'l administrators, public admin.

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.