Inspection Detail
Case Status: CLOSED |
Inspection: 1450977.015 - Ace Alternator And Starter Service, Inc.
|
Inspection Information - Office: Oklahoma City | ||||
Nr: 1450977.015 | Report ID: 0627700 | Open Date: 12/09/2019 | ||
Ace Alternator And Starter Service, Inc. | ||||
6216 Se 15th Street Midwest City, OK 73110 | Union Status: NonUnion | |||
SIC: | ||||
NAICS: 811111/General Automotive Repair | ||||
Mailing: 6216 Se 15th Street, Midwest City, OK 73110 | ||||
Inspection Type: | Fat/Cat | |||
Scope: | Partial | Advanced Notice: | N | |
Ownership: | Private | |||
Safety/Health: | Safety | Close Conference: | 12/09/2019 | |
Close Case: | 04/27/2020 | |||
Related Activity: | Type | ID | Safety | Health |
Referral | 1527460 | Yes | ||
Accident | 1544959 |
Case Status: CLOSED |
Accident Investigation Summary | ||||||
---|---|---|---|---|---|---|
Summary Nr: 122470.015 | Event: 01/10/2020 | Automotive Technician Is Burned When Fuel Catches On Fire | ||||
At 5:00 a.m. on January 10, 2020, an employee was working for a firm that perfor med automotive service. He was removing a fuel pump from an automobile. Fuel spi lled. It was ignited. In the fire, the employee suffered burns over 80 percent o f his body. He was killed. | ||||||
Keywords: automobile, automotive repair, burn, fire, gasoline, maintenance | ||||||
Inspection | Degree | Nature | Occupation | |||
1 | 1450977.015 | Fatality |