Inspection Detail
Case Status: OPEN |
Note: The following inspection has not been indicated as closed. Please be aware that the information shown may change, e.g. violations may be added or deleted. For open cases, in which a citation has been issued, the citation information may not be available for 5 days following receipt by the employer for Federal inspections or for 30 days following receipt by the employer for State inspections.
Inspection Information - Office: Ca Monrovia District Office | ||||
---|---|---|---|---|
Nr: 1447044.015 | Report ID: 0950644 | Open Date: 11/22/2019 | ||
Topline Nails, Inc | ||||
9302 Whittier Blvd. Pico Rivera, CA 90660 | Union Status: NonUnion | |||
SIC: | ||||
NAICS: 812113/Nail Salons | ||||
Mailing: 9302 Whittier Blvd., Pico Rivera, CA 90660 | ||||
Inspection Type: | Fat/Cat | |||
Scope: | Partial | Advanced Notice: | N | |
Ownership: | Private | |||
Safety/Health: | Safety | Close Conference: | 02/24/2020 | |
Close Case: | ||||
Related Activity: | Type | ID | Safety | Health |
Accident | 1518025 |
Case Status: OPEN |
Violation Summary | ||||||
---|---|---|---|---|---|---|
Serious | Willful | Repeat | Other | Unclass | Total | |
Initial Violations | 3 | 3 | ||||
Current Violations | 3 | 3 | ||||
Initial Penalty | $0 | $0 | $0 | $5,960 | $0 | $5,960 |
Current Penalty | $0 | $0 | $0 | $2,550 | $0 | $2,550 |
FTA Amount | $0 | $0 | $0 | $0 | $0 | $0 |
Violation Items | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
# | ID | Type | Standard | Issuance | Abate | Curr$ | Init$ | Fta$ | Contest | LastEvent | |
1. | 01001 | Other | 342(A) | 05/15/2020 | 06/19/2020 | $2,000 | $5,000 | $0 | 08/19/2020 | O - Administrative Law Judge Order | |
2. | 01002 | Other | 3203(A) | 05/15/2020 | 06/19/2020 | $150 | $260 | $0 | 08/19/2020 | O - Administrative Law Judge Order | |
3. | 01003 | Other | 5194(E) | 05/15/2020 | 06/19/2020 | $400 | $700 | $0 | 08/19/2020 | O - Administrative Law Judge Order |
Accident Investigation Summary | ||||||
Summary Nr: 124210.015 | Event: 11/13/2019 | Employee Is Trapped In Break Room During Flash Fire And Is K | ||||
At 8:30 p.m. on November 13, 2019, an employee was taking a break in an attic space that had been converted into a breakroom for employees at a Nail Salon. The employee was caught in the break room when a coworker who was retrieving a gallon of acetone from a shelf that was located above a hot dryer. The bottle slipped from her hands and caused a flash fire when the acetone spilled onto the hot dryer and the employee could not get out of the breakroom as the exit was blocked off by flames. The employee was killed. | ||||||
Keywords: acetone, fire | ||||||
Inspection | Degree | Nature | Occupation | |||
---|---|---|---|---|---|---|
1 | 1447044.015 | Fatality | Burn/Scald(Heat) | Occupation Not Listed |