Inspection Detail
Case Status: CLOSED |
Inspection Information - Office: Iowa | ||||
---|---|---|---|---|
Nr: 1429535.015 | Report ID: 0751910 | Open Date: 09/09/2019 | ||
Nutrien Ag Solutions | ||||
504 Clinton St Brayton, IA 50042 | Union Status: NonUnion | |||
SIC: | ||||
NAICS: 424910/Farm Supplies Merchant Wholesalers | ||||
Mailing: 504 Clinton St, Brayton, IA 50042 | ||||
Inspection Type: | Fat/Cat | |||
Scope: | Partial | Advanced Notice: | N | |
Ownership: | Private | |||
Safety/Health: | Safety | Close Conference: | 09/09/2019 | |
Close Case: | 11/04/2019 | |||
Related Activity: | Type | ID | Safety | Health |
Accident | 1495653 |
Case Status: CLOSED |
Accident Investigation Summary | ||||||
Summary Nr: 119683.015 | Event: 09/04/2019 | Employee Sustains Head Injuries And Is Killed | ||||
At 11:00 a.m. on September 4, 2019, an employee was working in the chemical warehouse and was found unresponsive to verbal communication. The employee sustained injuries to the back of his head and was killed. | ||||||
Keywords: warehouse, chemical, head, unresponsive | ||||||
Inspection | Degree | Nature | Occupation | |||
---|---|---|---|---|---|---|
1 | 1429535.015 | Fatality | Cut/Laceration | Occupation Not Listed |