Inspection Detail
Case Status: OPEN |
Note: The following inspection has not been indicated as closed. Please be aware that the information shown may change, e.g. violations may be added or deleted. For open cases, in which a citation has been issued, the citation information may not be available for 5 days following receipt by the employer for Federal inspections or for 30 days following receipt by the employer for State inspections.
Inspection: 1417696.015 - Par Electrical Contractors, Inc.
|
Inspection Information - Office: Ca Redding | ||||
Nr: 1417696.015 | Report ID: 0950623 | Open Date: 07/23/2019 | ||
Par Electrical Contractors, Inc. | ||||
Hwy 70 West Of Twain Lat 40.02609 Long 121.14091 N40 01.594' W121 08.404 Twain, CA 95984 | Union Status: Union | |||
SIC: | ||||
NAICS: 237130/Power and Communication Line and Related Structures Construction | ||||
Mailing: 4770 N. Belleview Avenue, Suite 300, Kansas City, MO 64116 | ||||
Inspection Type: | Fat/Cat | |||
Scope: | Partial | Advanced Notice: | N | |
Ownership: | Private | |||
Safety/Health: | Safety | Close Conference: | 01/10/2020 | |
Close Case: | ||||
Related Activity: | Type | ID | Safety | Health |
Accident | 1479218 |
Case Status: OPEN |
Serious | Willful | Repeat | Other | Unclass | Total | |
---|---|---|---|---|---|---|
Initial Violations | 6 | 6 | ||||
Current Violations | 6 | 6 | ||||
Initial Penalty | $90,000 | $0 | $0 | $0 | $0 | $90,000 |
Current Penalty | $90,000 | $0 | $0 | $0 | $0 | $90,000 |
FTA Amount | $0 | $0 | $0 | $0 | $0 | $0 |
# | ID | Type | Standard | Issuance | Abate | Curr$ | Init$ | Fta$ | Contest | LastEvent | |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Serious | 3203(A)(6) | 01/10/2020 | $9,000 | $9,000 | $0 | 01/10/2020 | C - Contested | ||
2. | 02001 | Serious | 3203(A)(7) | 01/10/2020 | $9,000 | $9,000 | $0 | 01/10/2020 | C - Contested | ||
3. | 03001 | Serious | 3328(A)(2) | 01/10/2020 | $18,000 | $18,000 | $0 | 01/10/2020 | C - Contested | ||
4. | 04001 | Serious | 3328(C) | 01/10/2020 | $18,000 | $18,000 | $0 | 01/10/2020 | C - Contested | ||
5. | 05001 | Serious | 29400006 B01 | 01/10/2020 | $18,000 | $18,000 | $0 | 01/10/2020 | C - Contested | ||
6. | 06001 | Serious | 29400006 D04 | 01/10/2020 | $18,000 | $18,000 | $0 | 01/10/2020 | C - Contested |
Accident Investigation Summary | ||||||
---|---|---|---|---|---|---|
Summary Nr: 118262.015 | Event: 07/22/2019 | One Employee Is Killed, One Is Injured In Fall From Scaffold | ||||
At 3:50 p.m. on July 22, 2019, Employees #1 and #2, employed by an electrical se rvices company, were working from a portable work platform, an A.B. Chance 12-fo ot Baker scaffold, that was attached to a newly installed 59-foot utility pole. The work platform separated from the pole, and both employees fell approximatel y 42 to 45 feet. Employee #1 was killed. Employee #1 was transported to the ho spital, admitted, and treated for fall-related injuries. | ||||||
Keywords: construction, equipment failure, fall, fall protection, falling object, installing, insulator, ladder, power lines, scaffold, utility pole, work platform | ||||||
Inspection | Degree | Nature | Occupation | |||
1 | 1417696.015 | Hospitalized injury | Electrical power installers and repairers | |||
2 | 1417696.015 | Fatality | Electricians |