Inspection Detail
Case Status: CLOSED |
Inspection Information - Office: Nevada Reno | ||||
---|---|---|---|---|
Nr: 1387110.015 | Report ID: 0953210 | Open Date: 03/13/2019 | ||
Verdi Television District | ||||
740 2nd St Verdi, NV 89439 | Union Status: NonUnion | |||
SIC: | ||||
NAICS: 921130/Public Finance Activities | ||||
Mailing: P.O. Box 221, Verdi, NV 89439 | ||||
Inspection Type: | Fat/Cat | |||
Scope: | Partial | Advanced Notice: | N | |
Ownership: | LocalGovt | |||
Safety/Health: | Health | Close Conference: | 08/08/2019 | |
Close Case: | 08/08/2019 | |||
Related Activity: | Type | ID | Safety | Health |
Accident | 1466932 |
Case Status: CLOSED |
Accident Investigation Summary | ||||||
Summary Nr: 117353.015 | Event: 03/01/2019 | Two Men Are Killed Due To Carbon Monoxide Poisoning | ||||
At 1:56 a.m. on March 1, 2019, two employees were performing maintenance work for television tower.The two employees were overcome with CO poisoning inside of maintenance building and were killed. | ||||||
Keywords: carbon monoxide, maintenance, inhalation | ||||||
Inspection | Degree | Nature | Occupation | |||
---|---|---|---|---|---|---|
1 | 1387110.015 | Fatality | Poisoning(Systemic) | Engineering technicians, n.e.c. | ||
2 | 1387110.015 | Fatality | Poisoning(Systemic) | Engineering technicians, n.e.c. |