Inspection Detail
Case Status: CLOSED |
Inspection Information - Office: Michigan Safety Gen | ||||
---|---|---|---|---|
Nr: 1344099.015 | Report ID: 0552652 | Open Date: 09/05/2018 | ||
Nagel Precision Inc | ||||
288 Dino Dr Ann Arbor, MI 48103 | Union Status: NonUnion | |||
SIC: | ||||
NAICS: 333517 | ||||
Mailing: 288 Dino Dr, Ann Arbor, MI 48103 | ||||
Inspection Type: | Fat/Cat | |||
Scope: | Partial | Advanced Notice: | N | |
Ownership: | Private | |||
Safety/Health: | Safety | Close Conference: | 12/11/2018 | |
Close Case: | 01/29/2019 | |||
Related Activity: | Type | ID | Safety | Health |
Accident | 1381561 |
Case Status: CLOSED |
Accident Investigation Summary | ||||||
Summary Nr: 109119.015 | Event: 09/05/2018 | Employee Is Found Unresponsive And May Have Been Electrocutr | ||||
At 12:05 p.m. on September 5, 2018, an employee returned from lunch and had been relaxing near an intersection of a conveyor and a machine. The employee was found unresponsive and possibly electrocuted when he made contact with the conveyor and machine at the same time. | ||||||
Keywords: unconsciousness, electrocuted | ||||||
Inspection | Degree | Nature | Occupation | |||
---|---|---|---|---|---|---|
1 | 1344099.015 | Fatality | Electric Shock | Occupation Not Listed |