Powered by GoogleTranslate

Occupational Safety and Health Administration OSHA

Inspection Detail

Case Status: PENALTIES REFERRED TO DEBT COLLECTION

Note: The following inspection has not been indicated as closed. Please be aware that the information shown may change, e.g. violations may be added or deleted. For open cases, in which a citation has been issued, the citation information may not be available for 5 days following receipt by the employer for Federal inspections or for 30 days following receipt by the employer for State inspections.

Inspection: 1339491.015 - Rainbow Construction Service, Llc

Inspection Information - Office: Atlanta East

Nr: 1339491.015Report ID: 0418100Open Date: 08/17/2018

Rainbow Construction Service, Llc
4523 Pine Drive
Forest Park, GA 30297
Union Status: NonUnion
SIC:
NAICS: 238160/Roofing Contractors
Mailing: 4523 Pine Drive, Forest Park, GA 30297

Inspection Type:Referral
Scope:Partial Advanced Notice:N
Ownership:Private
Safety/Health:Safety Close Conference:12/06/2018
Close Case:

Related Activity:TypeIDSafetyHealth
 Referral1371372 Yes  
Case Status: PENALTIES REFERRED TO DEBT COLLECTION

Violation Summary
Serious Willful Repeat Other Unclass Total
Initial Violations 2 2
Current Violations 2 2
Initial Penalty $6,097 $0 $0 $0 $0 $6,097
Current Penalty $6,097 $0 $0 $0 $0 $6,097
FTA Amount $0 $0 $0 $0 $0 $0

Violation Items
# ID Type Standard Issuance Abate Curr$ Init$ Fta$ Contest LastEvent
  1. 01001 Serious 19260152 F03 12/21/2018 01/18/2019 $3,880 $3,880 $0 Z - Issued
  2. 01002A Serious 19101200 E01 12/21/2018 01/18/2019 $2,217 $2,217 $0 Z - Issued
  3. 01002B Serious 19101200 G08 12/21/2018 01/18/2019 $0 $0 $0 Z - Issued
  4. 01002C Serious 19101200 H01 12/21/2018 01/18/2019 $0 $0 $0 Z - Issued

Accident Investigation Summary
Summary Nr: 108339.015Event: 08/15/2018Employee Incurs Severe Burns In Fire Caused By Roofing Adhes
At 1:38 a.m. on August 15, 2018, an employee was using a flammable solvent-based adhesive to install thermoplastic polyolefin membrane on a roof. A coworker had set up a propane torch to dry moisture accumulation on the roof when the employee walked too close to the torch. The employee's clothing caught fire and the employee panicked and ran into the area of the roof where the adhesive was being applied. The fire enveloped the employee and he received second and third degree burns to eighty percent of his body and was hospitalized.
Keywords: propane torch, fire, glue, roof, installing, flammable liquid, clothing, roofer, burn
Inspection Degree Nature Occupation
1 1339491.015 Hospitalized injury Burn/Scald(Heat) Roofers: Helpers

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.