Inspection Detail
Case Status: CLOSED |
Inspection Information - Office: Ft. Lauderdale | ||||
---|---|---|---|---|
Nr: 1334558.015 | Report ID: 0418800 | Open Date: 07/27/2018 | ||
Agm Ac Solutions Corp | ||||
2744 Sw 36th St. Coral Gables, FL 33133 | Union Status: NonUnion | |||
SIC: | ||||
NAICS: 238220/ Plumbing, Heating, and Air-Conditioning Contractors | ||||
Mailing: 7052 West 29th Ave, Hialeah, FL 33018 | ||||
Inspection Type: | Fat/Cat | |||
Scope: | Complete | Advanced Notice: | N | |
Ownership: | Private | |||
Safety/Health: | Safety | Close Conference: | 07/31/2018 | |
Close Case: | 12/19/2018 | |||
Related Activity: | Type | ID | Safety | Health |
Accident | 1364084 |
Case Status: CLOSED |
Accident Investigation Summary | ||||||
Summary Nr: 107849.015 | Event: 07/27/2018 | Employee Is Electrocuted While Installing Air Ducts | ||||
At 1:30 p.m. on July 27, 2018, an employee was installing air ducts inside an attic. During work, the employee contacted electrical wiring inside the attic and was electrocuted. | ||||||
Keywords: attic, electrocuted, duct | ||||||
Inspection | Degree | Nature | Occupation | |||
---|---|---|---|---|---|---|
1 | 1334558.015 | Fatality | Electric Shock | Heating, air conditioning, and refrig. mechanics |