Inspection Detail
Case Status: CLOSED |
Inspection Information - Office: Toledo | ||||
---|---|---|---|---|
Nr: 1326510.015 | Report ID: 0524700 | Open Date: 06/28/2018 | ||
Biofit Engineered Products Limited Partnership | ||||
15500 Biofit Way Bowling Green, OH 43402 | Union Status: Union | |||
SIC: | ||||
NAICS: 337214/Office Furniture (except Wood) Manufacturing | ||||
Mailing: P.O. Box 109, Waterville, OH 43566 | ||||
Inspection Type: | Referral | |||
Scope: | Partial | Advanced Notice: | N | |
Ownership: | Private | |||
Safety/Health: | Safety | Close Conference: | 06/28/2018 | |
Emphasis: | N:Amputate | Close Case: | 01/22/2019 | |
Related Activity: | Type | ID | Safety | Health |
Referral | 1351515 | Yes |
Case Status: CLOSED |
Violation Summary | ||||||
---|---|---|---|---|---|---|
Serious | Willful | Repeat | Other | Unclass | Total | |
Initial Violations | 3 | 1 | 4 | |||
Current Violations | 3 | 1 | 4 | |||
Initial Penalty | $21,988 | $0 | $0 | $6,467 | $0 | $28,455 |
Current Penalty | $13,192 | $0 | $0 | $3,881 | $0 | $17,073 |
FTA Amount | $0 | $0 | $0 | $0 | $0 | $0 |
Violation Items | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
# | ID | Type | Standard | Issuance | Abate | Curr$ | Init$ | Fta$ | Contest | LastEvent | |
1. | 01001 | Serious | 19100212 A03 II | 09/26/2018 | 10/05/2018 | $5,432 | $9,054 | $0 | I - Informal Settlement | ||
2. | 01002 | Serious | 19101030 F01 I | 09/26/2018 | 10/05/2018 | $3,880 | $6,467 | $0 | I - Informal Settlement | ||
3. | 01003 | Serious | 19101030 G02 I | 09/26/2018 | 10/05/2018 | $3,880 | $6,467 | $0 | I - Informal Settlement | ||
4. | 02001 | Other | 19040039 A02 | 09/26/2018 | 10/05/2018 | $3,881 | $6,467 | $0 | I - Informal Settlement |
Accident Investigation Summary | ||||||
Summary Nr: 106908.015 | Event: 06/23/2018 | Employee'S Finger Is Partially Amputated While Operating Alp | ||||
At 11:20 a.m. on June 23, 2018, an employee was operating an Alpine tube and pipe hydraulic bender. After placing a tube in the benders clamp, he activated the machine while his right hand was in the machine's point of operation (between the pipe and the clamp). As a result, the employee's right index finger was partially amputated after being pinched and fractured by the clamp. | ||||||
Keywords: point of operation, guard, finger, amputated, caught between | ||||||
Inspection | Degree | Nature | Occupation | |||
---|---|---|---|---|---|---|
1 | 1326510.015 | Non Hospitalized injury | Amputation | Machine operators, not specified |