Inspection Detail
Case Status: VIOLATIONS UNDER CONTEST |
Note: The following inspection has not been indicated as closed. Please be aware that the information shown may change, e.g. violations may be added or deleted. For open cases, in which a citation has been issued, the citation information may not be available for 5 days following receipt by the employer for Federal inspections or for 30 days following receipt by the employer for State inspections.
Inspection Information - Office: Bakersfield District Office | ||||
---|---|---|---|---|
Nr: 1313245.015 | Report ID: 0950647 | Open Date: 04/24/2018 | ||
K-Vac Environmental Services, Inc. | ||||
13210 Holloway Rd. Lost Hills, CA 93249 | Union Status: NonUnion | |||
SIC: | ||||
NAICS: 562112/Hazardous Waste Collection | ||||
Mailing: Po Box 1505, Rancho Cucamonga, CA 91729 | ||||
Inspection Type: | Accident | |||
Scope: | Partial | Advanced Notice: | N | |
Ownership: | Private | |||
Safety/Health: | Safety | Close Conference: | 11/07/2018 | |
Close Case: | ||||
Related Activity: | Type | ID | Safety | Health |
Accident | 1333791 |
Case Status: VIOLATIONS UNDER CONTEST |
Violation Summary | ||||||
---|---|---|---|---|---|---|
Serious | Willful | Repeat | Other | Unclass | Total | |
Initial Violations | 3 | 2 | 5 | |||
Current Violations | 3 | 2 | 5 | |||
Initial Penalty | $46,575 | $0 | $0 | $1,460 | $0 | $48,035 |
Current Penalty | $46,575 | $0 | $0 | $1,460 | $0 | $48,035 |
FTA Amount | $0 | $0 | $0 | $0 | $0 | $0 |
Violation Items | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
# | ID | Type | Standard | Issuance | Abate | Curr$ | Init$ | Fta$ | Contest | LastEvent | |
1. | 01001 | Other | 6760(A) | 10/20/2018 | 11/08/2018 | $975 | $975 | $0 | 12/21/2018 | - | |
2. | 01002 | Other | 3395(I) | 10/20/2018 | 11/08/2018 | $485 | $485 | $0 | 12/21/2018 | Z - Issued | |
3. | 02001 | Serious | 6786 | 10/20/2018 | $10,125 | $10,125 | $0 | 12/21/2018 | - | ||
4. | 03001 | Serious | 6815(C) | 10/20/2018 | 11/01/2018 | $16,200 | $16,200 | $0 | 12/21/2018 | - | |
5. | 04001 | Serious | 6851(A) | 10/20/2018 | 11/01/2018 | $20,250 | $20,250 | $0 | 12/21/2018 | - |
Accident Investigation Summary | ||||||
Summary Nr: 110212.015 | Event: 04/23/2018 | Several Employees Incurs Burns In A Natural Gas Leak | ||||
At 4:00 p.m. on April 23, 2018, several employees were conducting maintenance on a filter bank that had contained natural gas. A fire occurred while the employees were servicing the filter bank causing serious burn injuries to several employees. | ||||||
Keywords: burn, gas leak, natural gas, fire | ||||||
Inspection | Degree | Nature | Occupation | |||
---|---|---|---|---|---|---|
1 | 1313245.015 | Non Hospitalized injury | Burn/Scald(Heat) | Managers and administrators, n.e.c | ||
2 | 1313245.015 | Hospitalized injury | Burn/Scald(Heat) | Hazardous Materials Removal Worker | ||
3 | 1313245.015 | Hospitalized injury | Burn/Scald(Heat) | Hazardous Materials Removal Worker |