Case Status: CLOSED
Inspection: 1308231.015 - Bon L Manufacturing Company

Inspection Information - Office: Atlanta West

Nr: 1308231.015Report ID: 0418200Open Date: 04/11/2018

Bon L Manufacturing Company
25 Bonnell Street
Newnan, GA 30263
Union Status: Union
SIC:
NAICS: 331318 
Mailing: 25 Bonnell Street, Newnan, GA 30263

Inspection Type:Fat/Cat
Scope:Partial Advanced Notice:N
Ownership:Private
Safety/Health:Safety Close Conference:05/16/2018
Emphasis: L:ForkliftClose Case:11/07/2018

Related Activity:TypeIDSafetyHealth
 Accident1326983    
Case Status: CLOSED

Violation Summary
Serious Willful Repeat Other Unclass Total
Initial Violations 3 3
Current Violations 3 3
Initial Penalty $31,411 $0 $0 $0 $0 $31,411
Current Penalty $23,558 $0 $0 $0 $0 $23,558
FTA Amount $0 $0 $0 $0 $0 $0

Violation Items
# ID Type Standard Issuance Abate Curr$ Init$ Fta$ Contest LastEvent
  1. 01001 Serious 19100147 C04 I 10/09/2018 10/26/2018 $9,701 $12,934 $0 I - Informal Settlement
  2. 01002 Serious 19100147 C07 I A 10/09/2018 10/26/2018 $8,315 $11,086 $0 I - Informal Settlement
  3. 01003 Serious 19100303 G02 10/09/2018 10/26/2018 $5,543 $7,391 $0 I - Informal Settlement

Accident Investigation Summary
Summary Nr: 104643.015Event: 04/11/2018Employee Is Killed When Struck By Falling Furnace Door
At 12:00 p.m. on April 11, 2018, Employee #1 and a coworker were assigned to work on the Sow Preheater #1 furnace. They were to repair the rotary switch, the cable, and the door of the preheater. The employee raised the door via the control panel, to determine the clearance requirement of the door. The coworker stepped back to watch the height of the door and instructed the employee when to stop the upward travel of the door. Once the door was raised to the required height, the coworker marked the upper travel height using the JLG scissor lift that was on site. Once the door was stopped, the coworker turned away from the door to gather his tools. The employee left the control panel and walked under the door to obtain measurements for the headache bar. The supporting cable broke, causing the raised furnace door to fall, landing on the employee. Employee #1 was crushed and killed.
Keywords: struck by, door, falling object, powered industrial vehicle, furnace, crushed
Inspection Degree Nature Occupation
1 1308231.015 Fatality Cut/Laceration

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close