Inspection: 1303987.015 - Ppcie, Inc.

Inspection Information - Office: Ca San Diego

Nr: 1303987.015Report ID: 0950632Open Date: 03/22/2018

Ppcie, Inc.
1019 Costa Pacifica Waynull
Oceanside, CA 92054
Union Status: NonUnion
SIC:
NAICS: 238320/Painting and Wall Covering Contractors
Mailing: 1955 N. Main Stnull, Orange, CA 92865

Inspection Type:Accident
Scope:Partial Advanced Notice:N
Ownership:Private
Safety/Health:Safety Close Conference:08/13/2018
Close Case:03/04/2019

Related Activity:TypeIDSafetyHealth
 Accident1319636    
Case Status: CLOSED

Violation Summary
Serious Willful Repeat Other Unclass Total
Initial Violations 2 2 4
Current Violations 1 2 3
Initial Penalty $27,000 $0 $0 $840 $0 $27,840
Current Penalty $18,000 $0 $0 $2,335 $0 $20,335
FTA Amount $0 $0 $0 $0 $0 $0

Violation Items
# ID Type Standard Issuance Abate Curr$ Init$ Fta$ Contest LastEvent
  1. 01001 Other 1512(I) 08/13/2018 09/14/2018 $335 $420 $0 08/15/2018 O - Administrative Law Judge Order
Deleted 2. 01002 Other 5194(H)(2) 08/13/2018 09/14/2018 $420 $420 $0 08/15/2018 O - Administrative Law Judge Order
  3. 02001 Other 1509(A) 08/13/2018 $2,000 $9,000 $0 08/15/2018 O - Administrative Law Judge Order
  4. 03001 Serious 3328(A)(2) 08/13/2018 $18,000 $18,000 $0 08/15/2018 O - Administrative Law Judge Order

Accident Investigation Summary
Summary Nr: 107635.015Event: 03/09/2018Employee Using Spray Gun Punctures Hand
At 7:00 a.m. on March 9, 2018, Employee #1, a foreman employed by a painting com pany, was painting the exterior of a four-story apartment building. He was usin g a Titan Powrtwin 8900 Plus S-5 hydraulic piston spray gun. The spray gun had a maximum operating pressure of 3,300 pounds per square inch, a 5.5 horsepower e ngine, and a maximum volume flow of 9.5 liters per minute. As he was clearing a clog in the spray gun's tip guard, the trigger engaged, and paint was injected into his right hand. Emergency services, were called, and Employee #1 was trans ported to the hospital, admitted, and treated for the puncture wound.
Keywords: clogged, gunshot, paint, painter, pressure release, puncture, residential construction, unsecured
Inspection Degree Nature Occupation
1 1303987.015 Hospitalized injury Painters, construction and maintenance

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.