Note: The following inspection has not been indicated as closed. Please be aware that the information shown may change, e.g. violations may be added or deleted. For open cases, in which a citation has been issued, the citation information may not be available for 5 days following receipt by the employer for Federal inspections or for 30 days following receipt by the employer for State inspections.

Inspection: 1287806.015 - Robert Sean Looney

Inspection Information - Office: Dallas

Nr: 1287806.015Report ID: 0626300Open Date: 01/11/2018

Robert Sean Looney
2424 Swiss Avenue
Dallas, TX 75204
Union Status: NonUnion
SIC:
NAICS: 238140/Masonry Contractors
Mailing: 733 Somerset Court, Mansfield, TX 76063

Inspection Type:Fat/Cat
Scope:Complete Advanced Notice:N
Ownership:Private
Safety/Health:Safety Close Conference:01/11/2018
Emphasis: L:Constr6Close Case:

Related Activity:TypeIDSafetyHealth
 Accident1299489    
Case Status: PENALTIES REFERRED TO DEBT COLLECTION

Violation Summary
Serious Willful Repeat Other Unclass Total
Initial Violations 3 3
Current Violations 3 3
Initial Penalty $11,640 $0 $0 $0 $0 $11,640
Current Penalty $9,600 $0 $0 $0 $0 $9,600
FTA Amount $0 $0 $0 $0 $0 $0

Violation Items
# ID Type Standard Issuance Abate Curr$ Init$ Fta$ Contest LastEvent
  1. 01001 Serious 19260451 F06 04/05/2018 05/01/2018 $3,200 $3,880 $0 I - Informal Settlement
  2. 01002 Serious 19260451 F07 04/05/2018 05/01/2018 $3,200 $3,880 $0 I - Informal Settlement
  3. 01003 Serious 19260454 B 04/05/2018 05/01/2018 $3,200 $3,880 $0 I - Informal Settlement

Accident Investigation Summary
Summary Nr: 102226.015Event: 01/10/2018Employee Contacts An Overhead Power Line And Is Electrocuted
At 1:05 p.m. on January 10, 2018, an employee and coworkers were erecting a tubular welded frame scaffold in front of a commercial building in order to repair the top four feet of brick at the front of the building.The scaffold was erected four tiers high, near an energized, uninsulated power line (13.2 kV phase to phase). The minimum required clearance distance of 10 feet was not maintained. As the construction of the scaffold was almost complete with only the last few pieces of guardrail to be installed, the employee inadvertently contacted the power line with a 7-foot long piece of metal scaffolding. The employee was electrocuted as a result.
Keywords: electrocuted, power lines, scaffold
Inspection Degree Nature Occupation
1 1287806.015 Fatality Electric Shock Construction laborers

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.