Inspection: 127025948 - Tci Of Michigan Inc

Inspection Information - Office: Michigan Safety Cnst

Nr: 127025948Report ID: 0552651Open Date: 07/15/1999

Tci Of Michigan Inc
745 Lansing Ave
Jackson, MI 48202
Union Status: NonUnion
SIC: 1623/Water, Sewer, Pipeline, and Communications and Power Line Construction
Mailing: 2000 Cooper, Jackson, MI 49202

Inspection Type:Accident
Scope:Partial Advanced Notice:N
Ownership:Private
Safety/Health:Safety Close Conference:08/10/1999
Planning Guide: Safety-Construction Close Case:01/19/2000

Related Activity:TypeIDSafetyHealth
 Accident101401149    

Violation Summary
Serious Willful Repeat Other Unclass Total
Initial Violations 7 1 8
Current Violations 7 1 8
Initial Penalty $9,600 $0 $0 $0 $0 $9,600
Current Penalty $9,600 $0 $0 $0 $0 $9,600
FTA Amount $0 $0 $0 $0 $0 $0

Violation Items
# ID Type Standard Issuance Abate Curr$ Init$ Fta$ Contest LastEvent
  1. 01001 Serious 19100268 C 09/15/1999 09/20/1999 $1,500 $1,500 $0 A - Amendment
  2. 01002 Serious 19100268 F01 09/15/1999 09/20/1999 $1,500 $1,500 $0 A - Amendment
  3. 01003 Serious 19100268 F05 09/15/1999 09/20/1999 $1,500 $1,500 $0 A - Amendment
  4. 01004 Serious 19100268 M01 09/15/1999 09/20/1999 $1,500 $1,500 $0 A - Amendment
  5. 01005 Serious 19100268 M03 09/15/1999 09/20/1999 $1,500 $1,500 $0 A - Amendment
  6. 01006 Serious 19100268 M04 09/15/1999 09/20/1999 $1,500 $1,500 $0 A - Amendment
  7. 01007 Serious 4084320911 09/15/1999 09/20/1999 $600 $600 $0 A - Amendment
  8. 02001 Other 4084320506 09/15/1999 09/20/1999 $0 $0 $0 A - Amendment

Accident Investigation Summary
Summary Nr: 201403151Event: 07/14/1999Electric Shock - Ground Fault In Pole Ground
An employee was attaching a bonding jumper for a new communication cable strand. He was electrocuted when he contacted an energized ground on a utility pole.
Keywords: electrical, telecom work, communication cable, e tc, electrocuted, ground fault, strand installation, system grounding, utility pole
Inspection Degree Nature Occupation
1 127025948 Fatality Electric Shock Construction laborers

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.