Powered by GoogleTranslate

Occupational Safety and Health Administration OSHA

Inspection Detail

Case Status: CLOSED
Inspection: 1268792.015 - 317717154 - Boise Cascade Company

Inspection Information - Office: Or Bend

Nr: 1268792.015Report ID: 1054115Open Date: 06/05/2017

317717154 - Boise Cascade Company
62621 Highway 82
La Grande, OR 97850
Union Status: Union
SIC: 2493/Reconstituted Wood Products
NAICS: 321219/Reconstituted Wood Product Manufacturing
Mailing: Po Box 50, Boise, ID 83728

Inspection Type:Accident
Scope:Partial Advanced Notice:N
Ownership:Private
Safety/Health:Safety Close Conference:10/04/2017
Close Case:02/08/2018
Case Status: CLOSED

Violation Summary
Serious Willful Repeat Other Unclass Total
Initial Violations 1 1
Current Violations 1 1
Initial Penalty $7,000 $0 $0 $0 $0 $7,000
Current Penalty $7,000 $0 $0 $0 $0 $7,000
FTA Amount $0 $0 $0 $0 $0 $0

Violation Items
# ID Type Standard Issuance Abate Curr$ Init$ Fta$ Contest LastEvent
  1. 01001 Serious OAR 437-001-0760(1)(A)-3 10/19/2017 10/26/2017 $7,000 $7,000 $0 Z - Issued

Accident Investigation Summary
Summary Nr: 99615.015Event: 06/02/2017Four Employees Are Clearing Blockage In Boiler System And Su
At 10:16 p.m. on June 2, 2017, four employees were cleaning a boiler and clearing a blockage within the boiler when it went positive and expelled wood dust fuel that caused an explosion when it ignited. Employee #1 suffered multiple burns ranging from first degree to third degree on his hands and arms. Employee #2 suffered first and second degree burns to his hands and arms. Employee #3 was treated for a burn to his left cheek, and Employee #4 suffered abrasions to his hands and was treated at the scene. Employees #1 and #2 were treated at the Grande Ronde Hospital Emergency Department and were hospitalized. Employee # 1 was later transferred to the Oregon Burn Center at Legacy Emanuel Medical Center. Employee #3 was treated at the emergency department as well but was released after treatment.
Keywords: abrasion, burn, dust, fire, hand, face, explosion, boiler, arm
Inspection Degree Nature Occupation
1 1268792.015 Non Hospitalized injury Burn/Scald(Heat) Occupation not reported
2 1268792.015 Non Hospitalized injury Burn/Scald(Heat) Occupation not reported
3 1268792.015 Non Hospitalized injury Burn/Scald(Heat) Occupation not reported
4 1268792.015 Hospitalized injury Burn/Scald(Heat) Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close