Inspection Detail
Case Status: CLOSED |
Inspection Information - Office: Oklahoma City | ||||
---|---|---|---|---|
Nr: 1251246.015 | Report ID: 0627700 | Open Date: 07/31/2017 | ||
The Airport Business Center, L.L.C. | ||||
3114 S.W. 11th Street Lawton, OK 73501 | Union Status: NonUnion | |||
SIC: | ||||
NAICS: 531120/Lessors of Nonresidential Buildings (except Miniwarehouses) | ||||
Mailing: 1 S.W. 11th Street, Ste. 210, Lawton, OK 73501 | ||||
Inspection Type: | Fat/Cat | |||
Scope: | Complete | Advanced Notice: | N | |
Ownership: | Private | |||
Safety/Health: | Safety | Close Conference: | 07/31/2017 | |
Close Case: | 01/08/2018 | |||
Related Activity: | Type | ID | Safety | Health |
Accident | 1246755 |
Case Status: CLOSED |
Violation Summary | ||||||
---|---|---|---|---|---|---|
Serious | Willful | Repeat | Other | Unclass | Total | |
Initial Violations | 2 | 2 | ||||
Current Violations | 2 | 2 | ||||
Initial Penalty | $16,478 | $0 | $0 | $0 | $0 | $16,478 |
Current Penalty | $8,000 | $0 | $0 | $0 | $0 | $8,000 |
FTA Amount | $0 | $0 | $0 | $0 | $0 | $0 |
Violation Items | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
# | ID | Type | Standard | Issuance | Abate | Curr$ | Init$ | Fta$ | Contest | LastEvent | |
1. | 01001 | Serious | 19100028 B13 I | 12/12/2017 | 12/14/2017 | $2,000 | $3,803 | $0 | I - Informal Settlement | ||
2. | 01002A | Serious | 19100333 C03 I A 1 | 12/12/2017 | 12/14/2017 | $6,000 | $12,675 | $0 | I - Informal Settlement | ||
3. | 01002B | Serious | 19100332 B01 | 12/12/2017 | 12/28/2017 | $0 | $0 | $0 | I - Informal Settlement |
Accident Investigation Summary | ||||||
Summary Nr: 97710.015 | Event: 07/31/2017 | Employee Is Electrocuted By Overhead Power Line While Removi | ||||
At 8:00 a.m. on July 31, 2017, an employee was removing old weather stripping /sealant from a roof. The employee threw a long piece of weather stripping into a trash truck that was parked below. One end of the weather stripping touched an overhead power line while the other end was still in contact with the metal roofing and the employee was electrocuted. | ||||||
Keywords: electrical, overhead power line, electrocuted, metal decking, roof | ||||||
Inspection | Degree | Nature | Occupation | |||
---|---|---|---|---|---|---|
1 | 1251246.015 | Fatality | Electric Shock | Occupation Not Listed |