Powered by GoogleTranslate

Occupational Safety and Health Administration OSHA

Inspection Detail

Inspection: 123332348 - A/Z Corporation

Inspection Information - Office: Hartford

Nr: 123332348Report ID: 0112000Open Date: 01/21/1997

A/Z Corporation
Route 163
Montville, CT 06353
Union Status: NonUnion
SIC: 1731/Electrical Work
Mailing: 7 Lorenz Parkway, Ledyard, CT 06339

Inspection Type:Unprog Rel
Scope:Partial Advanced Notice:N
Ownership:Private
Safety/Health:Health Close Conference:01/23/1997
Close Case:05/09/1997

Related Activity:TypeIDSafetyHealth
 Accident100080019    
 Referral902554328   Yes

Violation Summary
Serious Willful Repeat Other Unclass Total
Initial Violations 1 1
Current Violations 1 1
Initial Penalty $3,000 $0 $0 $0 $0 $3,000
Current Penalty $800 $0 $0 $0 $0 $800
FTA Amount $0 $0 $0 $0 $0 $0

Violation Items
# ID Type Standard Issuance Abate Curr$ Init$ Fta$ Contest LastEvent
  1. 01001 Serious 19100147 C07 IIIA 03/14/1997 04/09/1997 $800 $3,000 $0 I - Informal Settlement

Accident Investigation Summary
Summary Nr: 200080018Event: 01/20/1997Four Employees Burned With Hot Water/Steam
Employees #1 through #4 were disconnecting the outlet flange on a sheet and tube heat exchanger. The flange disengaged, and a slug of steam and hot water shot out from the outlet port. All four workers sustained burns; Employees #1, #2, and #4 were hospitalized.
Keywords: unsecured, work rules, steam, heat exchanger, hot water, burn, maintenance, construction, lockout, accidental discharge
Inspection Degree Nature Occupation
1 123332348 Hospitalized injury Burn/Scald(Heat) Electricians

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close