Powered by GoogleTranslate

Occupational Safety and Health Administration OSHA

Inspection Detail

Inspection: 109421412 - Dutch Harbor Seafood, Ltd.

Inspection Information - Office: Bellevue

Nr: 109421412Report ID: 1032300Open Date: 09/16/1991

Dutch Harbor Seafood, Ltd.
Pier 91, Port Of Seattle
Seattle, WA 98053
Union Status: NonUnion
SIC: 3731/Ship Building and Repairing
Mailing: 15400 Ne 90th Street, Redmond, WA 98053

Inspection Type:Accident
Scope:Partial Advanced Notice:N
Ownership:Private
Safety/Health:Safety Close Conference:12/20/1991
Emphasis: L:ShipClose Case:12/02/1992

Violation Summary
Serious Willful Repeat Other Unclass Total
Initial Violations 4 2 1 7
Current Violations 5 1 1 7
Initial Penalty $4,500 $42,000 $0 $0 $0 $46,500
Current Penalty $4,400 $14,200 $0 $0 $0 $18,600
FTA Amount $0 $0 $0 $0 $0 $0

Violation Items
# ID Type Standard Issuance Abate Curr$ Init$ Fta$ Contest LastEvent
  1. 01001 Serious 19150007 A01 12/23/1991 12/27/1991 $880 $1,125 $0 01/15/1992 R - Review Commission
  2. 01002 Serious 19150052 A02 12/23/1991 12/27/1991 $880 $1,125 $0 01/15/1992 R - Review Commission
  3. 01003 Serious 19150052 B01 12/23/1991 12/27/1991 $880 $1,125 $0 01/15/1992 R - Review Commission
  4. 01004 Serious 19150052 B03 12/23/1991 01/27/1992 $880 $1,125 $0 01/15/1992 R - Review Commission
  5. 02001 Serious 19150052 B02 12/23/1991 12/27/1991 $880 $21,000 $0 01/15/1992 R - Review Commission
  6. 02002 Willful 19150052 B03 12/23/1991 12/27/1991 $14,200 $21,000 $0 01/15/1992 R - Review Commission
  7. 03001 Other 19150099 H 12/23/1991 01/27/1992 $0 $0 $0 01/15/1992 R - Review Commission

Accident Investigation Summary
Summary Nr: 14509731Event: 09/16/1991No One Injured When Fire Ignites On Fishing Vessel
Employees were cutting in a compartment on a fishing vessel and left for a coffee break without stationing a fire watch at the site. Within 10 minutes, another employee saw smoke rising out of the compartment. The vessel was evacuated; there were no injuries. Because the compartment contained polyurethane insulation, it took the fire department two days to extinguish the fire.
Keywords: insulator, work rules, fire, ship, compartment, cutting and burning
Inspection Degree Nature Occupation
1 109421412 Occupation Not Listed

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close