Accident: 99381.015 - Three Employees Are Killed When A Gin Pole Fails

Accident: 99381.015 -- Report ID: 0418800 -- Event Date: 09/27/2017
InspectionOpen DateSICEstablishment Name
1267080.01509/27/2017Tower King Ii, Inc.
At 4:00 p.m. on September 27, 2017, three employees were working from a gin pole that was attached to a communications tower. They were in the process of removing the pedestal at the top of the tower and lowering it to the ground, in preparation to install a transmission antenna. The gin pole system attachment components failed and fell to the ground, resulting in the death of the three employees connected to it.
Keywords: communication tower, gin pole, fall
End Use Proj Type Proj Cost Stories NonBldgHt Fatality
Other building Alteration or rehabilitation   950 X
Employee # Inspection Age Sex Degree Nature Construction
1 1267080.015 22 M Fatality Other FallDist:
FallHt:
Cause:
FatCause: Lifting operations
2 1267080.015 35 M Fatality Other FallDist:
FallHt:
Cause:
FatCause: Lifting operations
3 1267080.015 31 M Fatality Other FallDist:
FallHt:
Cause:
FatCause: Lifting operations

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.