Powered by GoogleTranslate

Occupational Safety and Health Administration OSHA

Accident Report Detail

Accident: 98973.015 - Employee Is Struck By Tree During Logging Operations And Is

Accident: 98973.015 -- Report ID: 1032500 -- Event Date: 09/01/2017
InspectionOpen DateSICEstablishment Name
1263227.01509/05/2017Kirk Short Logging
On September 1, 2017, an employee was felling trees. The employee was struck by and crushed by one of the trees that was felled, killing him.
Keywords: crushed, logging, struck by, tree felling
Employee # Inspection Age Sex Degree Nature
1 1263227.015 54 M Fatality

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close