Accident: 98785.015 - Five Employees Are Hospitalized After Exposure To High Level

Accident: 98785.015 -- Report ID: 0521100 -- Event Date: 09/05/2017
InspectionOpen DateSICEstablishment Name
1261641.01509/06/2017Monogram Appetizers, Llc
At 10:00 p.m. on September 5, 2017, five employees were working near a ventilate d natural gas fuel fryer system. All of the employees began experiencing headach es, nausea, weakness, and other symptoms. Approximately forty percent of the bur ner units for the natural gas fuel production fryer system had been replaced wit h the same burner units the day before. The ventilation system was not rebalance d after the burner unit replacements. The ventilations control system indicate d the ventilation system was working correctly, but it was not keeping up with t he carbon monoxide generated that was leaking from the fryer burner section into the employee work area. It was determined that the system needed additional fr esh air to be used by the new burner units. A reported carbon monoxide reading o f 313 ppm was taken in the area by responding fire fighters. All five employees were hospitalized overnight with elevated carboxyhemoglobin levels from exposure to carbon monoxide.
Keywords: carbon monoxide, carboxyhemoglobin, fatigue, fryer, headache, natural gas, nausea, toxic atmosphere, ventilation
Employee # Inspection Age Sex Degree Nature Occupation
1 1261641.015 23 M Hospitalized injury Production helpers
2 1261641.015 41 F Hospitalized injury Production helpers
3 1261641.015 57 F Hospitalized injury Production inspectors, checkers and examiners
4 1261641.015 26 M Hospitalized injury Production helpers
5 1261641.015 20 M Hospitalized injury Production helpers

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.