Accident Report Detail
Accident: 980524 - Employee'S Fingers Amputated In Malfunctioning Press
Accident: 980524 -- Report ID: 0551800 -- Event Date: 07/08/1989 | |||||||
Inspection | Open Date | SIC | Establishment Name | ||||
---|---|---|---|---|---|---|---|
107981409 | 08/11/1989 | 3443 | Modine Manufacturing Co | ||||
At approximately 4:15 p.m. on July 8, 1989, Employee #1, a processor for Modine Manufacturing Company in Logansport, IN, was placing a part into the dies of a Johnson 75 ton mechanical press, serial #M-1003. The press double tripped. Although Employee #1 was using pull out equipment and two-hand control buttons, his left hand was caught in the point of operation. The employee's index and middle fingers were amputated, and his hand sustained a contusion. The mechanical press was in bad condition and the anti-repeat mechanism failed. In addition, the pull out device was defective. | |||||||
Keywords:
pull back device, die, amputated, inadequate maint, power press, finger, equipment failure, two-hand control, point of operation, hand
| |||||||
Employee # | Inspection | Age | Sex | Degree | Nature | Occupation | |
1 | 107981409 | Hospitalized injury | Amputation | Punching and stamping press machine operators |