Accident: 97536.015 - Worker Is Run Over By Front End Loader, Incurs Multiple Inju

Accident: 97536.015 -- Report ID: 0521100 -- Event Date: 07/25/2017
InspectionOpen DateSICEstablishment Name
1249934.01507/26/2017Lunda Construction Co.
At 9:00 a.m. on July 25, 2017, Employee #1 and Coworkers #1 and #2, employed by a construction company, were engaged in the reconstruction of a highway bridge. Coworker #1, the site foreman, was operating a Volvo L110F front end loader PIN Number VCEL110FL00061930 with a Volvo fork attachment Model 83770 Style Number 03-16-001. He was using the front end loader to transport a Dipper Arm/Jib atta chment LOHO 2170 Style Number 200143 across the bridge within the construction z one. The jib attachment was rigged to the forks of the front end loader. Emplo yee #1 and Coworker #2 were holding onto the jib attachment so it would be perpe ndicular to the front end loader. As they approached a small gravel pile, Cowor ker #2 let go of the jib attachment to walk around the gravel. The jib attachme nt apparently shifted, and Employee #1 was pulled into the path of the front end loader and run over by a tire. Emergency services were called, and Employee #1 was transported to the hospital. He was admitted and treated for a compound fr acture and other injuries to the right heel, a degloving injury to the right for earm, a dislocated right shoulder, and a sprained left ankle.
Keywords: arm, bridge, construction, construction vehicle, foot, fracture, front end loader, highway, run over, struck by
End Use Proj Type Proj Cost Stories NonBldgHt Fatality
Bridge    
Employee # Inspection Age Sex Degree Nature Occupation Construction
1 1249934.015 38 M Hospitalized injury Construction laborers FallDist:
FallHt:
Cause: Other Activities-Installing Ornamental And Archite
FatCause:

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.