Accident: 96725.015 - Employee Amputates Finger When Struck By Pipe'S Guardrail

Accident: 96725.015 -- Report ID: 0419400 -- Event Date: 06/26/2017
InspectionOpen DateSICEstablishment Name
1243653.01506/28/2017Forterra Pipe & Precast, Llc
At approximately 9:00 a.m. on June 26, 2017, an employee was securing a roll of concrete wire to a manual holding device used to hold the roll of wire in positi on to allow wire to be pulled by production. The employee was inserting 3 inch O D by 9 feet 06 inch metal pipe inside a left support bracket used to position on e side of a roll of concrete wire. The pipe end that the employee was holding wa s resting along a guardrail to help align and hold the weight of the pipe as it was being inserted into the left bracket. The bracket where the 3 inch pipe was being inserted fell as the employee was holding the end of the 3 inch pipe. The gravity of the pipe and bracket falling forced the employees left pinky finger t o be struck by the 3 inch pipe against the guardrail resulting in amputation of the left end of pinky finger. The employee was hospitalized and treated for his injuries.
Keywords: amputation, caught between, falling object, finger, guardrail, material handling, struck by
Employee # Inspection Age Sex Degree Nature
1 1243653.015 43 M Non Hospitalized injury

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close