Accident Report Detail

Accident: 964676 - Employee Suffers Scalp Injury When Hair Catches In Shaft

Accident: 964676 -- Report ID: 0352440 -- Event Date: 01/22/1993
InspectionOpen DateSICEstablishment Name
11958664202/08/19932759Insta-Print, Inc.
Employee #1 was running a drill punch in a bindery operation. This drill punch has a 24 in. long 1 in. horizontal shaft that turns three drill punchers. The machine is activated by an OFF and ON switch. Once work has been set in place on the table and secured by clamp holders, a foot pedal is used to raise the table. The clamp holders are controlled by the same pedal. As the table is raised, hollow drill bits drill the paper. As Employee #1 leaned over slightly to move the finished work to a table, her long hair became wrapped around the horizontal shaft, removing a piece of scalp, skin, and hair that was 4 in. wide and 8 in. to 9 in. long. Employee #1, who also suffered a puncture wound in her forehead, required hospitalization.
Keywords: drill operator, hair, ppe, rotating shaft, scalp, work rules, caught by, drill press, inattention, puncture
Employee # Inspection Age Sex Degree Nature Occupation
1 119586642 Hospitalized injury Other Drilling and boring machine operators

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close