Accident: 956193 - Employees Face Injured When Ram Strikes Wedge

Accident: 956193 -- Report ID: 0950642 -- Event Date: 07/22/1992
InspectionOpen DateSICEstablishment Name
11207104811/23/19923429Ajax Forge Co.
On July 22, 1992, Employee #1 had just replaced the boards of a drop hammer and begun to operate it when one of the wedges holding the boards to the ram fell and bounced into the die area as the ram was coming down. The ram struck the wedge, knocking it into Employee #1's face. He suffered a broken palate, fractured jaw, and several broken teeth. Wedges had loosened and fallen before and there was no procedure to ensure that the wedges were properly secured.
Keywords: fracture, unsecured, work rules, drop hammer, struck by, flying object, face, ram
Employee # Inspection Age Sex Degree Nature Occupation
1 112071048 Hospitalized injury Fracture Forging machine operators

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.