Accident: 948513 - Employee Killed When Crushed In Trench By Excavator Bucket

Accident: 948513 -- Report ID: 0355111 -- Event Date: 01/05/1998
InspectionOpen DateSICEstablishment Name
12545465201/06/19981623Possie B. Chenault, Inc.
At approximately 4:15 p.m. on January 5, 1998, Employee #1 and coworkers were engaged in a pipe laying operation. They had just finished moving a trench box that was being used in the excavation when the bottom of the trench caved-in on the PCV pipe. Employee #1 entered the north end of the box to remove the dirt. While he was between the tracked excavator and the north end of the box, he motioned for the operator to move his bucket forward and into the box. In the process, the operator lost sight of Employee #1, and he was crushed and killed between the excavator bucket and the trench box.
Keywords: trench box, work rules, construction, earthmoving equip, trench, caught between, crushed, excavator, communication
End Use Proj Type Proj Cost Stories NonBldgHt Fatality
Highway, road, street Maintenance or repair $50,000 to $250,000 X
Employee # Inspection Age Sex Degree Nature Occupation Construction
1 125454652 Fatality Other Supervisors; plumbers, pipefitters & steamfitters FallDist:
FallHt:
Cause: Excavation
FatCause: Crushed/run-over/trapped of operator by operating

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.