Accident: 93966.015 - Machine Operator Is Entangled In Winder And Fractures Arm

Accident: 93966.015 -- Report ID: 0523900 -- Event Date: 03/08/2017
InspectionOpen DateSICEstablishment Name
1217893.01503/16/2017General Plastic Extrusions, Inc.
At 5:30 a.m. on March 8, 2017, Employee #1, employed by a manufacturer of plastic extrusions, was working at an extrusion machine. She was attempting to move the plastic web coming from the machine onto a rotating core of the winder. Employee #1 became entangled in the winder. Emergency services were called, and Employee #1 was transported to the hospital. She was admitted and treated for three fractures to her arm that required surgery.
Keywords: plastic mfg, lockout/tagout, machine guarding, fracture, caught in, rotating parts, entangled, arm
Employee # Inspection Age Sex Degree Nature Occupation
1 1217893.015 28 F Hospitalized injury Fracture Packaging and filling machine operators

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.