Powered by GoogleTranslate

Occupational Safety and Health Administration OSHA

Accident Report Detail

Accident: 92956.015 - Anhydrous Ammonia Leak At Plant With No Injuries

Accident: 92956.015 -- Report ID: 0636900 -- Event Date: 02/08/2017
InspectionOpen DateSICEstablishment Name
1208990.01502/08/2017Five Star Custom Foods
At approximately 7:15 a.m. on February 8, 2017, workers at a food processing pla nt when an alarm went off due to anhydrous ammonia leak. All 120 workers evacua ted with no injuries.
Keywords: accidental discharge, anhydrous ammonia, chemical
Employee # Inspection Age Sex Degree Nature
1 1208990.015 56 M Non Hospitalized injury

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close