Accident: 909218 - Employee Burned And Cut In Laboratory Explosion

Accident: 909218 -- Report ID: 0454510 -- Event Date: 03/03/1993
InspectionOpen DateSICEstablishment Name
12047670003/04/19934953Laidlaw Environmental Services (Field Serv.), Inc.
Employee #1, a lab technician, was attempting to categorize unknown lab quantity chemicals at a hazardous waste cleanup site so they could be properly disposed of. To determine the flammability of a small quantity of an unknown chemical, she used a hand held torch inside a lab hood. An explosion occurred, blowing out the front of the hood and causing burns and cuts to Employee #1 She was hospitalized.
Keywords: burn, flammable liquid, ppe, torch, explosion, laceration, chemical reaction, testing lab
Employee # Inspection Age Sex Degree Nature Occupation
1 120476700 Hospitalized injury Cut/Laceration Chemical technicians

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.