Accident: 90436.015 - One Employee Dies, One Hospitalized In Confined Space

Accident: 90436.015 -- Report ID: 0626700 -- Event Date: 11/04/2016
InspectionOpen DateSICEstablishment Name
1190055.01511/04/2016Freeflow Services, Llc
At approximately 9:45 a.m. on November 4, 2016, Employee #1, wearing a full face respirator, opened the hatch of ETS tanker T442 to initiate cleaning. It contained residue from hazardous waste. Employee #2 witnessed Employee #1 bend over the hatch area on top of the trailer as he walked by. As Employee #2 continued along the trailer toward the front he heard a loud thump and knew Employee #1 had fallen into the tanker. Employee #2 heard Employee #1 call out for help. Employee #2 immediately climbed the ladder of the trailer and looked inside and saw Employee #1 lying unconscious at the bottom. Employee #2 called to a coworker for a full face respirator, put on the respirator, and asked the coworker to help him, and entered the trailer. The coworker climbed the ladder and saw Employee #2 lose grip on Employee #1 and begin to stagger. The coworker reached out to Employee #2 by entering the space with his head, arm and shoulder, only to lose a finger grip on Employee #2 as he went unconscious and fell to the bottom of the trailer. The coworker ran to the office building to alert staff and get emergency assistance. Employee #1 died from asphyxiation due to high chemical vapor concentration and suppressed oxygen. Employee #2 was hospitalized.
Keywords: access/egress, non-pel overexposure, asphyxiated, confined space, hazardous waste, chemical, respirator
Employee # Inspection Age Sex Degree Nature Occupation
1 1190055.015 34 M Fatality Asphyxia Hazardous Materials Removal Worker
2 1190055.015 58 M Hospitalized injury Asphyxia Hazardous Materials Removal Worker

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close