Powered by GoogleTranslate

Occupational Safety and Health Administration OSHA

Accident Report Detail

Accident: 88618.015 - Employee Is Caught In Machinery And Killed

Accident: 88618.015 -- Report ID: 0213900 -- Event Date: 08/29/2016
InspectionOpen DateSICEstablishment Name
1175993.01509/08/2016Aluminum Shapes, Llc.
At 8:45 p.m. on August 29, 2016, an employee was retrieving a falling piece of a luminum metal under the table of an extruder. When the employee was retrieving the a piece of aluminum metal, another employee dropped the table engaging a bar that sweeps back and forth. The employee fractured his leg in two places and la ter died from the injury.
Keywords: conveyor, lockout/tagout
Employee # Inspection Age Sex Degree Nature Occupation
1 1175993.015 42 M Fatality Machine operators, not specified

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.